Zoll Aed Plus Defibrillator

Minimum Order Quantity 1 Piece
Type Automatic External Defibrillators
Brand ZOLL
Usage/Application Emergency
Operation Mode Automatic
Atmospheric Pressure Range 10 to 95% relative humidity, non-condensing
Battery Type Lithium Ion Battery

Description

AED Plus Specifications
Defibrillator Waveform: Rectilinear Biphasic

Defibrillator Charge Hold Time: 30 seconds

Energy Selection: Automatic preprogrammed selection (120J, 150J, 200J)

Patient Safety: All patient connections are electrically isolated

Charge Time: Less than 10 seconds with new batteries

Electrodes: ZOLL CPR-D-padz, pedi-padz® II or stat-padz® II

Self-test: Configurable automatic self-test from 1 to 7 days. Default = every 7 days. Monthly full-energy test (200J).

Automatic Self-Test Checks: Battery capacity, electrode connection, electrocardiogram and charge/discharge circuits, microprocessor hardware and software, CPR circuitry and CPR-D sensor, and audio circuitry

CPR: Metronome Rate: Variable 60 to 100 CPM

Depth: 3/4″ to 3.5″; 1.9 to 8.9 cm

Defibrillation Advisory: Evaluates electrode connection and patient ECG to determine if defibrillation is required Shockable Rhythms: Ventricular fibrillation with average amplitude >100 microvolts and wide complex ventricular tachycardia with rates greater than 150 BPM for adults, 200 BPM for pediatrics. For ECG Analysis Algorithm sensitivity and specificity, refer to AED Plus Administrator’s Guide. Patient Impedance

Measurement Range: 0 to 300 ohms

Defibrillator: Protected ECG circuitry

Display Format: Optional LCD with moving bar Size: 2.6″ x 1.3″; 6.6 cm x 3.3 cm Optional ECG Viewing Window: 2.6 seconds Optional ECG Display Sweep Speed: 25 mm/sec; 1″/sec Battery Capacity: Typical new (20°C) = 5 years (225 shocks) or 13 hours continuous monitoring. End of life designated by Red X (typical remaining shocks = 9).

Data Recording and Storage: 50 minutes of ECG and CPR data. If audio recording option is installed and enabled, 20 minutes of audio recording, ECG, and CPR data. If audio recording is disabled, 7 hours of ECG and CPR data. PC Minimum Requirements For Configuration and Patient Data Recovery: Windows® 98, Windows® 2000, Windows® NT, Windows® XP, Windows® 7, IBMcompatible PII with 16550 UART (or higher) computer. 64MB RAM. VGA monitor or better. CD-ROM drive. IrDA port. 2MB disk space. Device Size: (H x W x D) 5.25″x 9.50″ x 11.50″; 13.3 cm x 24.1 cm x 29.2 cm Weight: 6.7 lbs; 3.1 kg Power: User-Replaceable Batteries. 10 Type 123A Photo Flash lithium manganese dioxide batteries Device Classification: Class II and internally powered per EN60601-1

Design Standards: Meets applicable requirements of UL 2601, AAMI DF-39, IEC 601-2-4, EN60601-1, IEC60601-1-2 Environmental Operating Temperature: 32° to 122°F; 0° to 50°C Storage Temperature: -22° to 140°F; -30° to 60°C Humidity: 10 to 95% relative humidity, non-condensing Vibration: MIL Std. 810F, Min. Helicopter Test Shock: IEC 68-2-27; 100G

Altitude: -300 to 15,000 ft.; -91m to 4573 m Particle and Water Ingress: IP-55 CPR-D-padz

Shelf Life: 5 years

Conductive Gel: Polymer Hydrogel

Conductive Element: Tin

Packaging: Multilayer foil laminate pouch Impedance Class: Low Cable Length: 48 in (1.2 m) Sternum: Length: 6.1 in (15.5 cm); Width: 5.0 in (12.7 cm); Length, conductive gel: 3.5 in (8.9 cm); Width, conductive gel: 3.5 in (8.9 cm); Area, conductive gel: 12.3 sq in (79.0 sq cm) Apex: Length: 6.1 in (15.5 cm); Width: 5.6 in (14.1 cm); Length, conductive gel: 3.5 in (8.9 cm); Width, conductive gel: 3.5 in (8.9 cm); Area, conductive gel: 12.3 sq in (79.0 sq cm) Complete Assembly: Folded Length: 7.6 in (19.4 cm); Folded width: 7.0 in (17.8 cm); Folded height: 1.5 in (3.8 cm) Design Standards: Meets applicable requirements of ANSI/ AAMI/ISO DF-39-1993